Owon TDS Series Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Instrumentos de medida Owon TDS Series. OWON TDS Series User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - User Manual

TDS Series Touchscreen Digital Storage Oscilloscopes User Manual TDS7104 TDS8104 TDS8204 WWW.OWON.COM.HK

Página 2 - Branch:

4.Junior User Guidebook 5 4. Junior User Guidebook This chapter deals with the following topics mainly:  Introduction to the structure of the o

Página 3 - General Warranty

4.Junior User Guidebook 6 Introduction to the Structure of the Oscilloscope When you get a new-type oscilloscope, you should get acquainted with it

Página 4 - Table of Contents

4.Junior User Guidebook 7 Rear Panel 6543217 Figure 4-2 Rear Panel 1. USB Host port: It is used to transfer data when external USB equipment conne

Página 5

4.Junior User Guidebook 8 Control (key and knob) Area 87254613 Figure 4-3 Keys Overview 1. G knob (General knob): when a symbol appears in the

Página 6

4.Junior User Guidebook 9 User Interface Introduction 21345681126272312141720 1822211391015162524197 Figure 4-4 Illustrative Drawing of Display Int

Página 7 - Safety Symbols

4.Junior User Guidebook 10 11. The pointer shows the trigger level position of the source in trigger menu. 12. The waveform of Math. 13. The wav

Página 8 - Warning:

4.Junior User Guidebook 11 If it is found that the packaging carton or the foamed plastic protection cushion has suffered serious damage, do not thro

Página 9 - 3. General Characteristics

4.Junior User Guidebook 12 Figure 4-5 Auto set Check CH2, CH3 and CH4 by repeating Step 2 and Step 3. How to Implement the Probe Compensation Wh

Página 10 - 4. Junior User Guidebook

4.Junior User Guidebook 13 Figure 4-7 Adjust Probe How to Set the Probe Attenuation Coefficient The probe has several attenuation coefficients,

Página 11 - Front Panel

4.Junior User Guidebook 14 How to Use the Probe Safely The safety guard ring around the probe body protects your finger against any electric shock,

Página 12 - Rear Panel

July 2013 edition V1.0 Copy Right in this Manual © Lilliput Company. All rights Reserved. The Lilliput's products are under t

Página 13

4.Junior User Guidebook 15 Figure 4-10 Vertical Control Zone 1. Use the button "VERTICAL POSITION" knob to show the signal in the cente

Página 14

4.Junior User Guidebook 16 through touchscreen" on P18. Introduction to the Horizontal System Shown as Figure 4-11, there are a button and

Página 15

4.Junior User Guidebook 17 Figure 4-12 Trigger Control Zone 1. Press the "Trigger Menu" button and call out the trigger menu. With the

Página 16

4.Junior User Guidebook 18 Set the Vertical System through touchscreen Control the vertical position/voltage division of the selected channelSelect

Página 17

4.Junior User Guidebook 19 Set the Horizontal System through touchscreen Increase the time baseControl the horizontal positionDecrease the time bas

Página 18

4.Junior User Guidebook 20 Touch to switch between unselected/selected to control the vertical gesture on the left screen Control the vertical positi

Página 19

4.Junior User Guidebook 21 Control the horizontal position of Zoom WindowControl the horizontal position of Main WindowIncrease the time base of Main

Página 20

4.Junior User Guidebook 22 window to display the Cursor Measure Menu in the bottom menu.  Set the system time: Touch the time in the top right cor

Página 21

5.Advanced User Guidebook 23 5. Advanced User Guidebook Up till now, you have already been familiar with the basic operations of the function areas

Página 22

5.Advanced User Guidebook 24 How to Set the Vertical System The VERTICAL CONTROLS includes 5 menu buttons such as CH1 ~ CH4 and Math, and 8 knobs

Página 23 - Touch to select the channel

General Warranty Lilliput warrants that the product will be free from defects in materials and workmanship for a period of 3 years from the date of

Página 24

5.Advanced User Guidebook 25 below: (1) Press the CH1 button to show channel menu. (2) Select Coupling in the bottom menu. (3) Select DC in th

Página 25

5.Advanced User Guidebook 26 (1) Press the CH1 button to show channel menu. (2) Select BandWidth in the bottom menu. (3) Select Full in the righ

Página 26 - Press repeatedly to

5.Advanced User Guidebook 27 Window Rectangle Hanning Hamming Blackman Bartlett Kaiser Select window for FFT. Format Vrms dB Select Vrms for Format

Página 27 - 4.Junior User Guidebook

5.Advanced User Guidebook 28 2. Select FFT in the bottom menu. 3. Select Source in the right menu; select ① in the left source menu. 4. Sele

Página 28 - 5. Advanced User Guidebook

5.Advanced User Guidebook 29 Hamming Better solution for magnitude than Rectangle, and good for frequency as well. It has slightly better frequen

Página 29

5.Advanced User Guidebook 30 aliasing. So pay more attention to the relation between the frequency being sampled and measured. Use VERTICAL POSITION

Página 30

5.Advanced User Guidebook 31 time base. 2. SEC/DIV knob: it is used to set the horizontal scale factor in the main window or the zoom window. 3.

Página 31

5.Advanced User Guidebook 32 How to Set the Trigger System Trigger determines when TDS starts to acquire data and display waveform. Once trigger i

Página 32 - Using FFT function

5.Advanced User Guidebook 33 Coupling AC DC HF LF Block the direct current component. Allow all component pass. Block the high-frequency signal,

Página 33

5.Advanced User Guidebook 34 The description of the Pulse Width Trigger Menu is as follows: MENU SETTING INSTRUCTION Trigger Mode Pulse Set vertic

Página 34

i Table of Contents 1. General Safety Requirements ... 1 2. S

Página 35 - Information of

5.Advanced User Guidebook 35 Slew Rate Slew Rate = (High level - Low level) / Settings Threshold &SlewRate High level Low level Slew Rate Adjust

Página 36 - Zoom the Waveform

5.Advanced User Guidebook 36 with a frequency lower than 8 kHz.  HF Reject: HF Reject coupling attenuates all signals with a frequency higher than 1

Página 37 - Trigger Control

5.Advanced User Guidebook 37 Figure 5-2 Peak Detect mode, under which the burrs on the falling edge of the square wave, can be detected and the nois

Página 38 - 3. Pulse Width Trigger

5.Advanced User Guidebook 38 Figure 5-4 The displayed waveform after the noise is removed under the Average Mode, in which the average number of 16

Página 39 - 4. Slope Trigger

5.Advanced User Guidebook 39 Press the Acquire button; select Wave Display in the bottom menu, select Type in the right menu. You can switch between

Página 40 - &SlewRate

5.Advanced User Guidebook 40 3. When the XY Mode is turned on, the reference waveform that has been displayed will be removed from the display autom

Página 41

5.Advanced User Guidebook 41 To save the current screen image The screen image can be saved to internal/external storage in JPG, BMP or PNG formats.

Página 42

5.Advanced User Guidebook 42 display/remove reference waveforms" on P42. To save setup files Setup information includes acquisition informatio

Página 43

5.Advanced User Guidebook 43 3. Select the waveform file in file explorer (*.csv/*.bin), see "To select the path or file in file explorer"

Página 44 - XY Mode

5.Advanced User Guidebook 44 When entering the interface of editing name, there will be a keypad dialog that let you touch to enter names. The length

Página 45 - How to Save and Recall

ii To save the current screen image ...

Página 46

5.Advanced User Guidebook 45 How to Implement the Auxiliary System Function Setting ●Config To change the user interface language 1. Press the Ut

Página 47 - To save setup files

5.Advanced User Guidebook 46 ●Calibrate Press the Utility button and select Calibrate in the left menu. The description of Calibrate Menu is shown

Página 48 - To edit file names

5.Advanced User Guidebook 47 The description of Pass/Fail Menu is shown as the follows: Pass/Fail test: Detect whether the input signal is within the

Página 49 - To manage file

5.Advanced User Guidebook 48 Figure 5-6 Pass/Fail test Note: 1. When Pass/Fail is ON, if you enter XY mode, Pass/Fail will be closed; in the XY mo

Página 50 - ●Display

5.Advanced User Guidebook 49 How to Measure Automatically Press the Measure button to display the menu for the settings of the Automatic Measureme

Página 51 - ●Pass/Fail

5.Advanced User Guidebook 50 11. Select PK-PK in the left menu. 12. Select Add in the right menu, the PK-PK added completes, finish setting of CH2.

Página 52

5.Advanced User Guidebook 51 entire waveform. Vamp: Voltage between Vtop and Vbase of a waveform. Vtop: Voltage of the waveform's flat top,

Página 53 - ●System

5.Advanced User Guidebook 52 How to Measure with Cursors Press the Cursor button to display the cursor measurement function menu in the bottom menu

Página 54 - Measure

5.Advanced User Guidebook 53 Figure 5-10 Waveform of Voltage Cursor Measurement Carry out the steps below for the time cursor measurement of the c

Página 55

5.Advanced User Guidebook 54 Figure 5-11 Waveform of Time Cursor Measurement The Cursor Measurement for FFT mode: Perform the steps below for the

Página 56 - Fall Time

1.General Safety Requirements 1 1. General Safety Requirements Before any operations, please read the following safety precautions to avoid any pos

Página 57

5.Advanced User Guidebook 55 Figure 5-12 Wave of Vamp cursor measurement Carry out the steps below for the Frequency cursor measurement: 1. Press

Página 58

5.Advanced User Guidebook 56 Figure 5-13 Wave of Freq cursor measurement How to Use Autoscale This is a very useful function for first time users

Página 59

5.Advanced User Guidebook 57 4. Select Wave Period in the bottom menu, select in the right menu, shown as Figure 5-14. Figure 5-14 Autoscale H

Página 60

5.Advanced User Guidebook 58 Function Items Setting Acquisition Mode Current Vertical Coupling DC Vertical Scale Adjust to the proper division.

Página 61 - How to Use Autoscale

6.Communication with PC 59 6. Communication with PC TDS series digital storage oscilloscope support communications with a PC through USB or LAN port.

Página 62 - Autoset

6.Communication with PC 60 Using LAN Port Connect directly (1) Connection. Plug in the LAN line to the LAN port in the rear panel of the oscill

Página 63

6.Communication with PC 61 Figure 6-3 Set the network parameters of the Software (4) Set the network parameters of the oscilloscope. In the osci

Página 64 - 6. Communication with PC

6.Communication with PC 62 Figure 6-5 Set the network parameters of the computer (3) Set the network parameters of the Software. Run the software o

Página 65 - Using LAN Port

6.Communication with PC 63 Utility button, select Config in the left menu. Select Net Config in the bottom menu. Set the IP Address and Port to the s

Página 66 - Connect through a router

7.Demonstration 64 7. Demonstration Example 1: Measurement a Simple Signal The purpose of this example is to display an unknown signal in the ci

Página 67

2.Safety Terms and Symbols 2 2. Safety Terms and Symbols Safety Terms Terms in this manual. The following terms may appear in this manual: Warn

Página 68 - Touch to complete the

7.Demonstration 65 Figure 7-1 Measure Frequency and PK-PK value for a given signal Example 2: Gain of an Amplifier in a Metering Circuit The purpo

Página 69 - 7. Demonstration

7.Demonstration 66 Gain = Output Signal / Input signal Gain (db) = 20×log (gain) Figure 7-2 Waveform of Gain Measurement Example 3: Capturing a Sing

Página 70

7.Demonstration 67 through touchscreen" on P18). (10) Check the Trigger State Indicator on the top of the screen, if it is not Ready, push dow

Página 71

7.Demonstration 68 Example 4: Analyze the Details of a Signal Noise is very common inside most of the electronic signal. To find out what's in

Página 72

7.Demonstration 69 User would see a much reduced random noise level and make it easy to see more details of the signal itself. After applying Average

Página 73

7.Demonstration 70 (7) Switch XY Mode as ON. The oscilloscope will display the input and terminal characteristics of the network in the Lissajous

Página 74

7.Demonstration 71 Example 6: Video Signal Trigger Observe the video circuit of a television, apply the video trigger and obtain the stable video o

Página 75

8.Troubleshooting 72 8. Troubleshooting 1. Oscilloscope is powered on but no Display.  Check whether the power connection is connected properl

Página 76

9.Technical Specifications 73 9. Technical Specifications Unless otherwise specified, the technical specifications applied are for TDS series only

Página 77 - 8. Troubleshooting

9.Technical Specifications 74 Performance Characteristics Instruction Time delay between channel(typical) 150ps Horizontal System Sampling rate range

Página 78

2.Safety Terms and Symbols 3 To avoid body damage and prevent product and connected equipment damage, carefully read the following safety information

Página 79

9.Technical Specifications 75 Performance Characteristics Instruction Measurement Cursor △V and △T between cursors Automatic PK-PK, Max, Min, Vtop, V

Página 80

9.Technical Specifications 76 General Technical Specifications Display Display Type 8" touchscreen color LCD Display Resolution 800 (Horizon

Página 81

10.Appendix 77 10. Appendix Appendix A: Enclosure Standard Accessories:  4 Passive probes: 1.2 m, 1:1 (10:1)  1x CD (PC link application

Página 82 - 10. Appendix

3.General Characteristics 4 3. General Characteristics  Max 200MHz bandwidth, up to 2GS/s realtime sample rate  7.6M record length  Waveform

Comentários a estes Manuais

Sem comentários