Owon SDS Series Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Instrumentos de medida Owon SDS Series. OWON SDS Series User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
SDS Series
Smart Digital Storage Oscilloscopes
User Manual
SDS6062(V)
SDS7072(V)
SDS7102(V)
SDS8102(V)
SDS8202(V)
SDS8302
SDS9302
Note: "V" for VGA interface (optional), SDS8302 and SDS9302
including VGA interface as default.
WWW.OWON.COM.HK
Vista de página 0
1 2 3 4 5 6 ... 108 109

Resumo do Conteúdo

Página 1 - User Manual

SDS Series Smart Digital Storage Oscilloscopes User Manual SDS6062(V) SDS7072(V) SDS7102(V) SDS8102(V) SDS8202(V) SDS8302

Página 2 - Branch:

4.Junior User Guidebook 4. Junior User Guidebook This chapter deals with the following topics mainly:  Introduction to the structure of the os

Página 3 - General Warranty

7.Demonstration Example 6: Video Signal Trigger Observe the video circuit of a television, apply the video trigger and obtain the stable video out

Página 4 - Table of Contents

8.Troubleshooting 8. Troubleshooting 1. Oscilloscope is powered on but no Display.  Check whether the power connection is connected properly.

Página 5

9.Technical Specifications 9. Technical Specifications Unless otherwise specified, the technical specifications applied are for SDS series only, a

Página 6

9.Technical Specifications Performance Characteristics Instruction Bandwidth limit 20MHz, full bandwidth (not including SDS6062(V) ) Channel –chan

Página 7 - Safety Symbols

9.Technical Specifications Performance Characteristics Instruction 1GS/s 1.25GS/s 10K Single CH ≤1GS/s 10M 2GS/s 2.5GS/s 10K SDS9302 Dual CH ≤400MS/

Página 8 - Warning:

9.Technical Specifications Performance Characteristics Instruction SDS8202(V) ±10V(200mV~1V); ±100V(2V~10V) SDS8302 SDS9302 Analog bandwidth 60MHz,

Página 9 - 3. General Characteristics

9.Technical Specifications Performance Characteristics Instruction Communication port USB2.0, USB for file storage; LAN port; VGA interface (only

Página 10 - 4. Junior User Guidebook

9.Technical Specifications General Technical Specifications Display Display Type 8" Colored LCD (Liquid Crystal Display) Display Resolution

Página 11 - Front Panel

10.Appendix 10. Appendix Appendix A: Enclosure Standard Accessories:  A pair of Passive probe: 1.2 m, 1:1 (10:1)  1x CD (PC link applica

Página 12 - Right Side Panel

10.Appendix Appendix C: Battery Using Guide Figure 10-1 Battery level indicator Charging the oscilloscope Connect the power cord to a power so

Página 13 - Rear Panel

4.Junior User Guidebook Introduction to the Structure of the Oscilloscope When you get a new-type oscilloscope, you should get acquainted with its

Página 14

4.Junior User Guidebook Light off: Only powered by battery without connecting AC Power 4. Control (key and knob) area 5. Probe Compensation: Measu

Página 15

4.Junior User Guidebook flash disk needs to use this port. 2. USB Device port: It is used to transfer data when external USB equipment connects to t

Página 16

4.Junior User Guidebook Control (key and knob) Area Figure 4-5 Keys Overview 1. Menu option setting: H1~H5 2. Menu option setting: F1~F5 3. Me

Página 17

4.Junior User Guidebook User Interface Introduction Figure 4-6 Illustrative Drawing of Display Interfaces 1. Waveform Display Area. 2. The st

Página 18

4.Junior User Guidebook 11. The waveform of CH1. 12. The positions of two purple dotted line cursors measurements. 13. The yellow pointer sho

Página 19

4.Junior User Guidebook How to Implement the General Inspection After you get a new SDS series oscilloscope, it is recommended that you should mak

Página 20

4.Junior User Guidebook Connect the probe tip and the ground clamp to the connector of the probe compensator. 3. Press the "Autoset" Butt

Página 21

4.Junior User Guidebook Overcompensated Compensated correctly Under compensated Figure 4-8 Displayed Waveforms of the Probe Compensation 3.

Página 22

May. 2014 edition V1.6.7 Copy Right in this Manual © Lilliput Company. All rights Reserved. The Lilliput's products are under

Página 23

4.Junior User Guidebook Figure 4-10 Attenuation Switch Caution: When the attenuation switch is set to 1X, the probe will limit the bandwidth o

Página 24 - 5. Advanced User Guidebook

4.Junior User Guidebook menu; turn the M knob to choose Adjust. Press H2 button to choose the option "Self Cal"; run the program after eve

Página 25

4.Junior User Guidebook  Turn the vertical "VOLTS/DIV" knob and change the "Vertical Scale Factor (Voltage Division)", it c

Página 26 - SDS7072(V)

4.Junior User Guidebook Introduction to the Trigger System As shown in Figure 4-14, there are one knob and three buttons make up "TRIGGER CON

Página 27

5.Advanced User Guidebook 5. Advanced User Guidebook Up till now, you have already been familiar with the basic operations of the function areas,

Página 28

5.Advanced User Guidebook How to Set the Vertical System The VERTICAL CONTROLS includes three menu buttons such as CH1 MENU, CH2 MENU and Math,

Página 29

5.Advanced User Guidebook The description of the Channel Menu is shown as the following list: Function Menu Setting Description Coupling DC AC GRO

Página 30

5.Advanced User Guidebook Figure 5-2 DC Coupling Oscillogram Figure 5-3 AC Coupling Oscillogram 2. To adjust the probe attenuation For correct

Página 31

5.Advanced User Guidebook (1) Press the CH1 MENU button to show CH1 SETUP menu. (2) Press the H3 menu selection, the Probe menu will display at

Página 32

5.Advanced User Guidebook Figure 5-5 Measure Current 4. To invert a waveform Waveform inverted: the displayed signal is turned 180 degrees again

Página 33 - Using FFT function

General Warranty Lilliput warrants that the product will be free from defects in materials and workmanship for a period of 3 years from the date of

Página 34

5.Advanced User Guidebook Figure 5-6 Original Waveform Figure 5-7 Inverted Waveform 5. To set bandwidth limit (SDS6062(V), SDS7072(V) does no

Página 35

5.Advanced User Guidebook (3) Press the F1 button to select the Band Limit as full band. The high frequency of the signal will be allowed to pas

Página 36

5.Advanced User Guidebook Window Rectangle Blackman Hanning Hamming Select window for FFT. Format dB Vrms Select dB for Format. Select Vrms for Fo

Página 37 - Set Window

5.Advanced User Guidebook Figure 5-9 Waveform resulted from CH1 +CH2 Using FFT function The FFT (fast Fourier transform) math function mathematic

Página 38 - Window Expansion

5.Advanced User Guidebook Type Characteristics Window Rectangle Best solution for frequency, worst for magnitude. Best type for measuring the fr

Página 39 - Trigger Control

5.Advanced User Guidebook Figure 5-10 Rectangle window Notes for using FFT  Use Zoom function to magnify the FFT waveform if necessary.  Use

Página 40 - 2. Video Trigger

5.Advanced User Guidebook The analytic resolution of this control knob changes with the vertical division. 2. The VOLTS/DIV knob is used to reg

Página 41 - 3. Slope Trigger

5.Advanced User Guidebook Function Menu Description Main (Main Time Base) The setting of the horizontal main time base is used to display the wave

Página 42 - 4. Pulse Width Trigger

5.Advanced User Guidebook Figure 5-14 Window Setting Window Expansion Press the H3 menu selection button and choose Zoom. As a result, the window

Página 43 - Alternate trigger

5.Advanced User Guidebook How to Set the Trigger System Trigger determines when DSO starts to acquire data and display waveform. Once trigger is

Página 44 - Slope) menu list:

Table of Contents 1. General Safety Requirements ... 1 2. Safe

Página 45 - Pulse) menu list:

5.Advanced User Guidebook The Edge Trigger Menu is shown as Figure 5-16. Figure 5-16 Edge trigger menu Edge menu list: Menu Settings Instructio

Página 46

5.Advanced User Guidebook Figure 5-17 Video trigger menu Video menu list: MENU SETTING INSTRUCTION Single Mode Video Set vertical channel trigger t

Página 47

5.Advanced User Guidebook Set slope condition; turn the M knob to set slope time. Threshold &SlewRate High level Low level Slew rate Adju

Página 48

5.Advanced User Guidebook Mode Holdoff Auto Normal Single Holdoff Reset Acquire waveform even no trigger occurred Acquire waveform when trigger oc

Página 49 - (only for

5.Advanced User Guidebook 2. Alternate trigger (Trigger Mode: video) Alternate trigger (Trigger Type: video) Menu is shown as Figure 5-21. Figure 5

Página 50 - Persist

5.Advanced User Guidebook Threshold High level Low level Slew rate Turn the M knob to set the High level Turn the M knob to set Low level Slew rat

Página 51 - XY Format

5.Advanced User Guidebook selected as a trigger source whatever displayed or not.  Ext Trig: The instrument can be triggered from a third source w

Página 52 - Trig Freq

5.Advanced User Guidebook How to Operate the Function Menu The function menu control zone includes 8 function menu buttons: Measure, Acquire, Util

Página 53

5.Advanced User Guidebook The description of the Record Length Menu is shown as follows: Function Menu Setting Description Length 1000 Choose the

Página 54

5.Advanced User Guidebook Figure 5-27 The displayed waveform after the noise is removed under the Average Mode, in which the average number of 16 i

Página 55

How to Implement the Auxiliary System Function Setting ... 63 How to Measure Automat

Página 56

5.Advanced User Guidebook Display Type: With the F1 menu selection button pushed down, you can shift between Vect and Dots types. The differences b

Página 57

5.Advanced User Guidebook OFF, 1second, 2second, 5second and Infinity. When the "Infinity" option is set for Persist time, the measuring p

Página 58

5.Advanced User Guidebook Operation steps: 1. Press the Display button and call out the Display Set Menu. 2. Press the H3 menu selection butto

Página 59

5.Advanced User Guidebook How to Save and Recall a Waveform Press the Save button, you can save the waveforms, settings or screen images. The menu

Página 60

5.Advanced User Guidebook Setting Setting1….. Setting8 The setting address Save Save the current oscilloscope setting to the internal storage Load

Página 61 - To recall waveform

5.Advanced User Guidebook Figure 5-34 Wave Saving Tip: Whatever the Type of save menu is set, you can save the waveform by just pressing the Co

Página 62

5.Advanced User Guidebook End and storeClose the keyboardSwitch between capital and smallDelete the last character Figure 5-35 Edit the File Name Fo

Página 63 - wave are the same as

5.Advanced User Guidebook 4. Right click 1 or 2 red mark area, choose Format. And system will pop up a warning message, click Yes. Figure 5-37: f

Página 64

5.Advanced User Guidebook Figure 5-39: Formatting U disk 7. Check whether the U disk is FAT32 with allocation unit size 4096 after formatting. Us

Página 65

5.Advanced User Guidebook Figure 5-40: Reload Disk 4. Right click 1 or 2 red mark area, choose Format. Figure 5-41: Choose format 5. Set File Sy

Página 66

1.General Safety Requirements 1. General Safety Requirements Before any operations, please read the following safety precautions to avoid any poss

Página 67

5.Advanced User Guidebook 6. Click Apply at the top left of the menu. Then click Yes on the pop-up warning to begin formatting. Figure 5-43: Appl

Página 68 - ●Config

5.Advanced User Guidebook To cut waveform: 1. Connect U-disk to SDS series oscilloscope 2. Press Save to call out the save menu 3. Press the H1

Página 69 - ●Adjust

5.Advanced User Guidebook Figure 5-47: Choose storage device (2) Select USBDEVICE, enter Next Level. Turn the knob or press / direction key to

Página 70

5.Advanced User Guidebook Tips: 1. Normally the frequency, amplitude, and offset of the recalled wave are the same as the wave being cut, but when t

Página 71 - ● Pass/Fail

5.Advanced User Guidebook Figure 5-50 Wave Record Playback: Play back the wave recorded or saved. Playback menu shows as follows: Menu Setting Inst

Página 72

5.Advanced User Guidebook Figure 5-51 Wave Playback Storage: Save the current wave according to the start frame and end frame set. Storage menu sho

Página 73 - ● Output

5.Advanced User Guidebook To use wave record function, do as follows: (1) Press Save button. (2) Press H1 button, turn the M knob to choose Record

Página 74 - ● LAN Set

5.Advanced User Guidebook Operate Play Stop Begin to record Stop recording Note: Both of the waveforms of Channel 1 and Channel 2 will be recorded.

Página 75 - Measure

5.Advanced User Guidebook Figure 5-55: Play back waveform by software How to Implement the Auxiliary System Function Setting ●Config Press the Ut

Página 76

5.Advanced User Guidebook ●Display Press the Utility button and turn the M knob to select the Display to go to the following menu. Figure 5-5

Página 77

2.Safety Terms and Symbols 2. Safety Terms and Symbols Safety Terms Terms in this manual. The following terms may appear in this manual: Warni

Página 78

5.Advanced User Guidebook The description of Adjust Menu is shown as the follows: Do Self Cal (Self-Calibration) The self-calibration procedure can

Página 79

5.Advanced User Guidebook 4. Press H4 again to begin probe checking and the checking result will occur after 3s; Press any other key to quit. Figu

Página 80

5.Advanced User Guidebook The description of Pass/Fail Menu is shown as the follows: Pass/Fail test: Detect whether the input signal is within the l

Página 81

5.Advanced User Guidebook Figure 5-62 Pass/Fail test Note: 1. When Pass/Fail is ON, if XY or FFT is ready to run, then Pass/Fail will be closed;

Página 82

5.Advanced User Guidebook ● LAN Set Using the LAN port, the oscilloscope can be connected with a computer directly, or through the router to conn

Página 83 - How to Use Autoscale

5.Advanced User Guidebook How to Measure Automatically Press the Measure button to display the menu for the settings of the Automatic Measurement

Página 84

5.Advanced User Guidebook automatic measurement cannot be performed in the following situation: 1) On the saved waveform. 2) On the mathematical wav

Página 85 - Autoset

5.Advanced User Guidebook The automatic measurement of voltage parameters The SDS series oscilloscopes provide automatic voltage measurements includ

Página 86

5.Advanced User Guidebook Figure 5-54 shows a pulse with some of the time measurement points. Figure 5-69 Rise Time: Time that the leading edge of

Página 87 - 5.Advanced User Guidebook

5.Advanced User Guidebook Figure 5-70 CURS MEAS Menu The description of the cursor measurement menu is shown as the following table: Function M

Página 88 - 6. Communication with PC

2.Safety Terms and Symbols Warning: The channels should adopt common basis during measuring. To prevent short circuits, the 2 probe ground must n

Página 89 - Using LAN Port

5.Advanced User Guidebook Figure 5-71 Waveform of Voltage Cursor Measurement Carry out the following operation steps for the time cursor measurem

Página 90 - Connect through a router

5.Advanced User Guidebook Figure 5-72 Waveform of Cursor Measurement The Cursor Measurement for FFT mode: Press the Cursor button to display the

Página 91

5.Advanced User Guidebook Source Math FFT Display the channel for the cursor measure. When carrying out the cursor measurement, the position of Curs

Página 92 - Using COM Port

5.Advanced User Guidebook Cursor2 by turning the VERTICAL POSITION knob of CH1 and CH2. Increment window shows two cursors difference value and t

Página 93 - 7. Demonstration

5.Advanced User Guidebook Autoscale ON OFF Turn on Autoscale. Turn off Autoscale. Mode Follow-up and adjust both vertical and horizontal settings

Página 94

5.Advanced User Guidebook is not available. 3. At the mode of XY and STOP status, pressing Autoset to enter into Autoscale, DSO switches to YT mode

Página 95

5.Advanced User Guidebook Trigger Level Mid-point Setting Trigger Mode Auto Display Format YT Judge waveform type by Autoset Five kinds of typ

Página 96

5.Advanced User Guidebook the settings of the Save function menu when the Type is Wave. For more details, please see "Save Function Menu"

Página 97

6.Communication with PC 6. Communication with PC SDS series digital storage oscilloscope support communications with a PC through USB, LAN or COM po

Página 98

6.Communication with PC Using LAN Port Connect directly (1) Connection. Plug in the LAN line to the LAN port in the right side panel of the osc

Página 99

3.General Characteristics 3. General Characteristics  Bandwidth: 60MHz — 300 MHz;  Sample rate(real time): 500MS/s — 3.2GS/s;  Dual channel,

Página 100

6.Communication with PC Figure 6-3 Set the network parameters of the OWON Oscilloscope Software (4) Set the network parameters of the oscilloscope

Página 101 - 8. Troubleshooting

6.Communication with PC set the IP address to 192.168.1.71, Subnet mask is 255.255.255.0, Default gateway is 192.168.1.1. Figure 6-5 Set the netw

Página 102

6.Communication with PC (4) Set the network parameters of the oscilloscope. In the oscilloscope, press the Utility button and press H1 button, turn

Página 103

7.Demonstration 7. Demonstration Example 1: Measurement a Simple Signal The purpose of this example is to display an unknown signal in the circ

Página 104

7.Demonstration settings of channel 2. Then, the period, frequency, mean and peak-to-peak voltage will be displayed at the bottom left of the screen

Página 105

7.Demonstration of the screen (see Figure 7-2). (9) Calculate the amplifier gain with the following formulas. Gain = Output Signal / Input signal G

Página 106

7.Demonstration (6) Press the Trigger Menu button to display the Trigger menu. (7) Press the H1 button to display the Trigger Type menu. (8) Pr

Página 107 - Pack:2s2p 7.4V/8000mAh

7.Demonstration Example 4: Analyze the Details of a Signal Noise is very common inside most of the electronic signal. To find out what's insi

Página 108 - 10. Appendix

7.Demonstration (2) Press the H1 button to display ACQU Mode menu. (3) Press the F3 button, turn the M knob and observe the waveform obtained from

Página 109

7.Demonstration (4) Turn the VOLTS/DIV knob, making the amplitudes of two signals equal in the rough. (5) Press the Display button and recall th

Modelos relacionados SDS5032E | SDS-E Series |